Shimada, Yoshihiro (2003) Storage of Authentic Sample for Biological Monitoring of Organic Solvents. 中国学園紀要, 2 . pp. 1-7. ISSN 1347-9350
| PDF - Published Version 572Kb |
Official URL: http://ci.nii.ac.jp/naid/110004706266/
Abstract
An external standard added the hippuric acid, m-methylhippuric acid and mandelic acid to the artificial urine and human urine were prepared for the quality control of biological monitoring. Thereafter, the specimens were kept at 25OC for 1, 2 and 4 weeks after freeze-drying, and change in concentrations during storage was examined by high performance liquid chromatography. The ratio of the concentrations of the three acids and creatinine after freeze-drying compares to that before storage was about 99 per cent or above under the storage condition at 25°C for 4 weeks.
| 出版物タイトル(別言語): | Journal of Chugokugakuen |
|---|---|
| Item Type: | Article |
| Additional Information: | この論文は国立情報学研究所によって電子化された。 |
| Uncontrolled Keywords: | artificial urine, freeze-drying, quality control, hippuric acid, m-methylhippuric acid, mandelic |
| Subjects: | 400:自然科学 > 490:医学. 薬学 > 491:基礎医学 > 491.3:生理学 |
| Divisions: | 中国学園大学 中国短期大学 |
| Copyright Holders: | 中国学園大学/中国短期大学 |
| ID Code: | 1 |
| Deposited On: | 26 Feb 2010 19:24 |
| Last Modified: | 01 Apr 2011 12:00 |